Which utility serves your lot
- Pacific Palisades (City of Los Angeles): LADWP is the utility, and the Los Angeles Department of Building and Safety (LADBS) issues the electrical permit.
- Altadena (unincorporated LA County): SCE is the utility, and LA County Public Works issues the electrical permit.
- Malibu and other areas outside the City of LA: usually SCE. Check the address on your last electric bill if you are unsure.
Not sure which applies? Send us the lot address for a temporary power quote and we will tell you which utility and permit office handle it.
Side by side: LADWP vs. SCE
| Step | LADWP (Pacific Palisades) | SCE (Altadena) |
|---|---|---|
| Electrical permit | LADBS, pulled first | LA County Public Works general electrical permit |
| Utility request | Take the LADBS permit to an LADWP payment center and apply | An SCE service request number is required for temporary power, requested online |
| Overhead or underground | Must match the lot's prior service; a pole dip can be either, and overhead is typically faster and cheaper | In SCE targeted undergrounding areas, SCE sets the service connection requirements |
| Typical 200A utility charge | About $1,200 overhead, or about $3,720 underground ($370 deposit + $3,350 balance) | Set by SCE for your service |
| Pole placement | Overhead: 10 to 100 feet from the serving pole. Underground: within 30 feet of the service lateral at the property line | SCE sets the service point |
| Rebuild help | Palisades Inspections and Support Center, 16925 Marquez Ave; PalisadesRebuild@LADWP.com | SCE disaster recovery centers and the Altadena electric rebuild page |
Utility charges are paid to the utility. LADWP lists its figures as estimates that can change with scope and amperage.
Underground service on rebuild lots
Both utilities are moving more rebuild areas underground, which changes what goes on your lot:
- LADWP underground temporary service: call 811 (DigAlert) before digging. You install the pole and the conduit to the LADWP lateral, following LADWP standard H-168, with no more than 225 degrees of bends. LADWP inspects the conduit and pole before anything is covered, and LADBS also inspects the pole.
- SCE targeted undergrounding: LA County advises a panel that accepts both overhead and underground service, and at least 2-inch Schedule 40 or 80 PVC conduit to the SCE service point, inspected before burial.
GDV Utilities builds both overhead and underground temporary service and coordinates the trench and conduit inspections.
Tips for rebuild owners and builders
- Start the utility request with the building permit. Rebuild areas have long queues.
- Ask whether your street is being undergrounded before choosing overhead temporary service.
- Keep the pole clear of the building pad and the future driveway, so it stays put through framing.
- Plan the permanent panel location early, so the temporary pole doesn't block it.
More on rebuild power: temporary power for fire rebuilds, Pacific Palisades, Altadena and Malibu.